USI GAS DETECTORS

Click below to view our selection of gas detection products

Portable Gas Detector

Wall-mount Gas Detector/Monitor

Two Stage Alarm - Controller

Single and Multichannel Gas Monitor / Alarm in Nema 4 Enclosure

Two Stage Alarms in Single and Multichannel Unit - Controller

Sensor Data Transmitter (SDT) Gas Detector

Portable Gas Detector

The portable toxic gas or combustible gases detector with audio/visual alarms and meter display is ideal for confined space monitoring. This piece of gas detection equipment is compact, light weight, and battery-operated. With built-in charger and Ni-Cad batteries allows the unit 10 hours of continuous operation. The handheld gas monitor with the sensor (no mechanical pump) and 5 feet of wire provides local area gas measuring. Analog meter, or 4-digit large LCD digital display indicates PPM or % LEL. Shoulder held carrying case and instrument case are also included. 0-1 VDC output for data acquisition is optional.

Portable Gas Detector

The portable toxic gas or combustible gases detector with audio/visual alarms and meter display is ideal for confined space monitoring. This piece of gas detection equipment is compact, light weight, and battery-operated. With built-in charger and Ni-Cad batteries allows the unit 10 hours of continuous operation. The handheld gas monitor with the sensor (no mechanical pump) and 5 feet of wire provides local area gas measuring. Analog meter, or 4-digit large LCD digital display indicates PPM or % LEL. Shoulder held carrying case and instrument case are also included. 0-1 VDC output for data acquisition is optional.

FEATURES

 Rugged, compact, light weight with shoulder carrying case and instrument case
 Uses a UL approved solid state sensor with 1 year warranty (estimated life over 10 years)
 Audio/visual alarms
 Low battery warning light
 Accurate Analog or Digital reading for PPM or %LEL
 Rechargeable Ni/Cad Battery and built in battery charger
 Fast warm up time 3-4 minutes and response time
 Sensor high poison resistant to sulphur, lead, silicone and halogenated compounds
 115, or 220 V AC line charge

SPECIFICATIONS - CONTROLLER

Dimensions: 8"H x 5"W x 3"D
Operating Temp: -10F to +150F
Meter Display: Analog PPM or % LEL; or Optional 4 digits LCD indicates PPM or % LEL
Power: 3.6VDC Ni-Cad Battery
Power Usage: 2.0 Watt Maximum
Operating Hours: 10 hours continuous (minimum)
Battery Signal: Visual Yellow LED indicates low battery
Battery Charger: Built in charger, 115 VAC or Optional 220 VAC
Panel Control: Zero and Span Adjustments
Alarms: Visual Red LED, Audio Buzzer 75dB
Panel Indicators: Power On (Green LED), in-charge (Orange LED)
Weight: 2.0 lbs (13 lbs in case)